Report's DE events don't fired.
KB-20240729-01
Version
XFRX 22.5
Symptoms
- Process report within XFRX#INIT don't fired events BeforeOpenTables, OpenTables, CloseTables and AfterCloseTables.
- Process report within XFRX#LISTENER fired events BeforeOpenTables, OpenTables, CloseTables and AfterCloseTables.
- Events Init and Destroy is runs.
Cause
Wrong evaluation stored values of properties AutoOpenTables and AutoCloseTables.
Workaround
Sets AutoOpenTables and AutoCloseTables to .T. in report's DE.